Meaning
Non-destructive analytical methods in industrial manufacturing measure the thickness and elemental composition of metal coatings on a substrate. This measurement technique, known as xrf metrology, uses secondary X-rays emitted from a sample that has been excited by a primary X-ray source. The process is used in printed circuit board fabrication to verify compliance with coating thickness specifications.
Its precision is bounded by the density of the coating material and the overlap of adjacent spectral lines.
Measurement Principle
When primary X-rays strike the sample, they dislodge inner-shell electrons from the target atoms. As outer-shell electrons fall into the vacancies, they emit X-rays of a characteristic energy unique to each element. The spectrometer detects these emitted photons and measures their intensity to determine the quantity of each element present.
This intensity is proportional to the thickness of the coating layer up to a material-dependent saturation limit.
Calibration Practice
Accurate thickness measurements require the use of reference standards with known compositions and thicknesses. These standards are measured regularly to calibrate the detector response and account for drift in the X-ray tube intensity.
Coating Analysis
Factories apply this analytical tool to monitor the deposition of multi-layer finishes like electroless nickel immersion gold. The technique can measure multiple layers simultaneously, providing rapid feedback on the performance of individual plating baths. This speed allows operators to make real-time adjustments to the process line before defects occur.
By tracking these measurements over time, quality managers can predict when a plating bath will require maintenance.