Meaning
Ultrasonic non-destructive evaluation relies on artificial calibration reflectors to quantify internal material discontinuities. Quality assurance technicians perform flat bottom hole detection to establish gain settings and sizing thresholds for internal voids. The procedure correlates signal echo amplitude from flat-drilled holes with reflection characteristics of natural flaws in metal forgings and plates.
Sound propagation limits restrict this detection method to planar boundaries perpendicular to the incoming acoustic beam path. Slanted discontinuities or irregular volumetric voids require specialized angled beam inspection techniques.
Calibration Standard
Machined reference blocks feature flat bottom holes of precise diameter drilled to varying sound path depths. Ultrasonic transducers sweep across test blocks to generate distance amplitude correction curves on flaw detector screens. Acoustic attenuation differences between reference blocks and production parts demand transfer correction adjustments.
Standardized calibration establishes consistent amplitude baseline values across different inspection hardware.
Amplitude Response
Sound waves reflecting from planar geometry generate sharp, well-defined acoustic signals. Signal height directly mirrors the cross-sectional area of the artificial reflector at specific depths. Higher reflection amplitudes indicate larger internal discontinuities.
Acceptance Limit